Shenzhen Baoan Medical Supply Co.,Ltd
5 1

USA Newest Medrad Mark 7 CT /MRI /ANGIO Injector 1200psi Syringes

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Browse by Category

Contact us

Shenzhen Baoan Medical Supply Co.,Ltd
[China]

Address
No6.shenkeng road ,shenkeng industrial zone , henggang ,liuyue ,longgang  Shenzhen Guangdong
Phone
86-0755-84042030
Contact name
Brant Zheng

Quick Information

  • Brand Name: BOON
  • Place of Origin: China
  • Model Number : 300108
  • Material : PP
  • Disposable : YES
  • EO sterile : YES
  • OEM : YES
  • KFDA : YES

Description

USA Newest Medrad Mark 7 CT /MRI /ANGIO  Injector 1200psi Syringes 

1.CT syringe :  (Single) 1-200ml syringe , 1-1500mm connecting tube , 1-J tube      50sets per case 
              (Dual)   2- 200ml syringe, 1-1500mm Y (T) connecting tube, 2-J tube  20sets per case
2.MR syringe :2-65ml syringe, 1-T type connecting tube , 2 - Spikes                 50sets per case
             65ml/115 ml syringe,  1-T type connecting tube , 2 - Spikes           50sets per case
             60ml /60ml syringe ,   1-T type connecting tube , 2 - Spikes          50sets per case
3.DSA syringe: 1-150ml syringe , 1-J tube                                         50sets per case
Sterile High -Pressure Angiographic Syringes and Accessories for single-use
BOON" Sterile High-Pressure Angiographic Syringe and Accessories for single use . Strict comply with ISO9001 and ISO13485 quality management system, producing in the one hundred thousand class cleanness workshop.
For use with digital subtraction angiography (DSA), computer control tomography (CT), magnetic resonance imaging (MRI) in the examination, using for various types of high pressure injection equipment respective.

Syringe Filling

  1. NOTE: One person should fill and arm the injector. If you must change the injector operator, be certain that the second operator verifies that the syringe is properly filled and that any air is eliminated.
  2. Tilt the injector head (or the syringe interface module) up.
  3. Advance the plunger to full forward position.
  4. Remove the protective cover from the syringe luer tip and attach a sterile filling device onto the tip of the syringe. Fill straw, or spike.
  5. Transfer the contrast media into the syringe by one of following methods:
  6. Fill Straw: raise the contrast bottle until the Fill Straw is fully inserted. The end of the Fill Straw should be near the bottom of the contrast bottle.
  7. Spike: prepare the bottle or container of contrast and/or saline solution. Push the bottle or bag onto the Filling Device until the seal is punctured.
  8. NOTE: Use Fill Straw or equivalent device to reduce the volume and size of air bubbles drawn into the syringe during filling. It is more difficult to remove the air bubbles if you use smaller diameter tubes, such as catheter-over-needle, or a tube longer than 10 in.(25cm.)
  9. Aspirate contrast media into the syringe.
  10. If the syringe has dot indicators use them to help you detect the presence of contrast media in the syringe. Verify that the Syringe disposable dot indicators are round in the filled portion of the syringe. The rounded shape of the dot indicators varies according to the type of contrast media, but an oblong shape indicates the presence of air. Rounded dot indicators do not indicate the total absence of air bubbles in the syringe tip.
* Refer to the injector operation manual for further instructions.
 
 
Expelling Air & Attaching the Connector Tubing
  1. After you fill the syringe, you must expel all air from the syringe and then attach the connector tubing. To do so:
  2. Remove the filling device and expel air from the syringe. Do not hit the syringe to remove air bubbles. Reverse the plunger 3 to 5 ml, then, if applicable, rock the injector head on the pivot to dislodge the bubbles. Expel the remaining air.
  3. If you are using a Y low pressure connector tubing, attach shorter side of the Y to the contrast syringe and the longer side of the Y to the saline syringe. Do not reverse the piston plunger after you have attached the tubing.
  4. Verify that the tubing is not kinked or obstructed.
  5. (If your injector does not have a manual knob, proceed to Step 6.) Use the manual knob to advance the syringe plunger to provide
  6. Prime the connector tubing and make certain that the air is expelled.
  7. Verify that all the air has been expelled from the syringe and fluid path.
  8. Attach the connector tube to the vascular entry device.
  9. Tilt the injector head (or syringe interface module) down.
* Refer to the injector operation manual for further instructions.
 
Removing the Syringe
  1. To detach the syringe when the procedure has been completed, Remove it from the injector head. Discard all used components.
 
* Refer to the injector operation manual for further instructions.
 
  1. Check the integrity of each primary package before use!
  2. Confirm syringe model and injector model compatibility per Table 1 above.
  3. Remove the syringe from the package. Attach the syringe to the injector according to the injector instructions for use.
  4. Use the injector to push the piston of the syringe to the front of the barrel.
  5. Remove the sheath from the conical fitting. Assemble the J shape tube/ spike on the conical fitting of the syringe.
  6. Draw the required contrast media or saline into the syringe at the lowest speed of the injector to prevent air leakage.
  7. Remove the J shape tube/spike from the syringe; discard it per the hospital or local regulations. Do not reuse!
  8. Remove the protective cap from the conical fitting of the high pressure tube. Attach the tube to the syringe.
  9. Attach the I.V. catheter or contrast media catheter to the other conical fitting of the high pressure tube.
  10. Expel the air in the catheter and tube.
  11. Inject the contrast media or saline in accordance with the instruction for use of the injector.
  12. After the injection, disconnect the I.V. catheter or contrast media catheter and the high pressure tube.  Remove the syringe from the injector.
  13. Discard the syringe, tube and catheter immediately per hospital or local regulations.
 


 


Certificates

  • CE : 0197
  • FDA : K151960

Price

  • Price Condition : FOB
  • Delivery Port : shenzhen

Packaging & Delivery

  • Packing :50pcs per box
  • Packaging Size : 535 x 385 x 415  Millimeters
  • Package Weight : 10  Kilograms
  • Delivery Lead Time : 15days after receive payment
  • Minimum Order : 500
  • Supply Ability : 150000pcs per month

Product Image

  • USA Newest Medrad Mark 7 CT /MRI /ANGIO  Injector 1200psi Syringes  image

Related products from premium suppliers on EC21

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Brant Zheng
Shenzhen Baoan Medical Supply Co.,Ltd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Syringe
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.